Roof plates usually are welded to supporting structure.
Non frangible roof.
Frangible definition is readily or easily broken.
However in the context of tanks the word has a specific meaning and is defined in the main tank construction standards bsen 14015 and api650.
Frangible definition easily broken.
The securement of the annular link mechanism to the rim and the roof is such as to permit.
Synonym discussion of frangible.
It can be achieved when part of the welds between cover plates and structures has decreased height.
Most frangible toys are not suitable for young children.
In such tanks the roof to shell joint is intended to fail in the event of overpressurization venting the tank and containing any remaining fluid.
Frangible is a word that means easily broken.
B supported fixed roofs.
Such relatively weak roof to shell joints are known as frangible roof joints.
A tank with a diameter of 7m 23 0 cannot have a frangible roof per 5 10 2 6.
Considering the project above the roof thickness is 9 5 mm and aws recommends a minimum weld size of 3 16 4 8mm and also there is the platform structure which stiffens the roof.
A frangible roof joint forming a flexible gastight connection between a tank shell and a roof comprising an annular link mechanism sealingly secured at or adjacent a first edge thereof to a rim of the tank and sealingly secured at or adjacent a second edge thereof to the periphery of the roof.
The concept of frangible roof only applies to flat bottom cone roof tanks with limited roof apex angle.
How to use frangible in a sentence.
C one way to obtain a frangible joint is when the roof plates are welded to the compression ring with a 3mm seal weld only and when the roof plates are not fixed to any roof supporting structure.
Guidance is also provided on how to determine the actual frangibility of tanks built before 1985 the date where frangibility became known as a design requirement.
Frangible bullets are often used by shooters engaging in close quarter combat training to avoid ricochets.
This paper presents the results of an investigation into the frangible joint behavior of tanks designed to api 650 rules.
Frangible bullets are typically made of non toxic metals and are frequently used on green ranges and outdoor ranges where lead abatement is a concern.
You will be required to provide a vent capable of relieving the emergency venting set forth in api 2000.
Targets are placed on steel backing plates that serve to completely fragment the bullet.